Over 50 Years of Gas Detection
The Macurco product line has offered fixed gas detection equipment for residential, commercial, and light industrial applications since 1972. Over the years, Macurco has provided many gas detection options for several different gases, including ammonia, refrigerants, carbon monoxide, nitrogen dioxide, propane, methane, and even special calibrations. Though there have been some changes, the one thing that has not changed is Macurco’s commitment to quality and value. See the list of discontinued products below. Click on the links to see product brochures from across the years.
Click on the links to see product brochures from across the years.
Macurco Inc. (2022-Present)
Aerionics Inc. (2012-Present)
3M Macurco (2006-2012)
Aerion Technologies Inc. (2001-2006)
Macurco Inc. (1972-2001)
Type | Discontinued Products | Current Replacement |
---|---|---|
Portable | MP100 Series | AimSafety Series |
Explosion Proof | EX Series | TracXP Series |
Air Quality | AQC-12 | CM-12 |
Air Quality | AQC-21 | CM-6 |
Ammonia | AD-1 | TX-6-AM |
Ammonia | AD-12 | TX-6-AM |
Carbon Dioxide | CD-6/ CD-6H | CD-6MC |
Carbon Monoxide | CM-4-20 | CM-6* |
Carbon Monoxide | CM-S1 | CM-E1 |
Carbon Monoxide | CS102A | CM-6* |
Carbon Monoxide | SS101 | CM-6 |
Carbon Monoxide | SS101H | CM-6 |
Carbon Monoxide | SS102H | CM-6* |
Carbon Monoxide | SS102HA | CM-6* |
Carbon Monoxide | SS102HC1 | CM-6* |
Carbon Monoxide | SS103-1 | CM-6 |
Carbon Monoxide | WCO1-B | CM-6 |
Carbon Monoxide | CM-3 | CM-6 |
Carbon Monoxide | CM-2B | CM-6 |
Carbon Monoxide | CM-21A | CM-6 |
Carbon Monoxide | CM-1 | CM-6 |
Carbon Monoxide | CM-11 | NA |
Carbon Monoxide | CM-13 | CM-E1* |
Carbon Monoxide | CM-13a | CM-E1* |
Carbon Monoxide | CM-14A | CM-E1* |
Carbon Monoxide | CM-15 | CM-E1* |
Carbon Monoxide | CM-15A | CM-E1* |
Carbon Monoxide | CM-16A | CM-E1* |
Carbon Monoxide | CM-1B | CM-6 |
Carbon Monoxide | CM-1-ND | CM-6 |
Carbon Monoxide | CM-2 | CM-6 |
Combustible | GD-1-SPC-NG | GD-2A |
Combustible | GD-1-SPC-PRO | GD-2A |
Combustible | GD-21 | GD-12 |
Combustible | GT-11 | GD-6* |
Combustible | GT-11A | GD-6* |
Combustible | GD-1 | GD-2B |
Combustible | GD-1S | GD-6 |
Combustible | GD-1D | GD-6 |
Combustible | 4S1B | GD-12 |
Combustible | 4S1C | GD-12 |
Combustible | 4S1D | GD-12 |
Combustible | 4S1D-1-BR | GD-12 |
Combustible | 4S1D-1-BR-220 | GD-12 |
Control Panel | SS103-10A | DVP-120* |
Control Panel | SS103-3 | DVP-120* |
Control Panel | SS103-3A | DVP-120* |
Control Panel | SS103-5A | DVP-120* |
Hydrogen | HD-21-1-BR | GD-12 |
Hydrogen | HD-12 | GD-6 |
Hydrogen | HD-11 | GD-6 |
Nitrogen Dioxide | ND-1 | TX-6-ND |
Nitrogen Dioxide | ND-2 | TX-6-ND |
Refrigerants | RD-6/RD-12 | Aireshield |
Refrigerants | RD-1 | Aireshield |
Refrigerants | FT-11 | Aireshield |
Refrigerants | FD-12-BR | Aireshield |
Refrigerants | FD-21 | Aireshield |
Refrigerants | FD-12-SPC | Aireshield |
Refrigerants | FD-12 | Aireshield |
Refrigerants | FD-11 | Aireshield |
Refrigerants | RD-2 | Aireshield |
Calibration Kit | OX-FCK | Cal-Kit-1 (Order Gas Separately) |
Calibration Kit | CD-6B-FCK | Cal-Kit-4 (Order Gas Separately) |
Calibration Kit | CX-FCK | Cal-Kit-2 (Order Gas Separately) |
Calibration Kit | RD-FCK | Cal-Kit-3 (Order Gas Separately) |
Calibration Kit | CD-FCK | Cal-Kit-4 (Order Gas Separately) |
Calibration Kit | HS-FCK | Cal-Kit-2 (Order Gas Separately) |
Calibration Kit | ND-FCK | Cal-Kit-2 (Order Gas Separately) |
Calibration Kit | GDP-FCK | Cal-Kit-1 (Order Gas Separately) |
Calibration Kit | GDH-FCK | Cal-Kit-1 (Order Gas Separately) |
Calibration Kit | GDM-FCK | Cal-Kit-1 (Order Gas Separately) |
Calibration Kit | CM-FCK | Cal-Kit-1 (Order Gas Separately) |
CM-E1*
The CM-E1 is 9-32VDC powered and fits into a single gang box. The CME1-IAK adapter plate is required to retrofit 2-gang type (CM-15/15A) detector installations. The CM-E1 will not replace VAC powered detectors/installations.
CM-6*
The CM-6 is a 12-24VAC or 12-32VDC. The CM-6 uses a 4-20mA analog output only and will not function with older control panels that require 1-2. 88VDC analog output.
GD-6*
The GD-6 is a 12-24VAC or 12-32VDC. The GD-6 uses a 4-20mA analog output only and will not function with older control panels that require 1-5VDC analog output.
DVP-120*
The DVP-120 Control Panel operates on 4-20mA analog inputs from the remote detectors. Older Macurco control panels (SS103) operated on 1-2.88VDC analog inputs from the remote detectors.